Hangzhou Hangguo General Equipment Co., Ltd. has been established since December, 2000. As a subsidiary of XIZI Clean Energy Equipment Manufacturing Co,.tld.(Stock code:002534)the Company specializes in the design and manufacture of auxiliary engine and heavy duty equipment for boilers. The company has produced 115 sets of flue gas bypass systems and 152 sets of flue gas baffle doors, covering all continents in the world.
Diverter Damper Pillar Page Preview
Diverter Damper Manufacturer in China | One-Inlet Two-Outlet Flue Gas Diverters for HRSG and Bypass Stack
A diverter damper is the change valve of a gas turbine bypass system: one inlet, two outlets, installed horizontally behind the gas turbine so exhaust can flow either into the HRSG or up the bypass stack. Hangzhou Hangguo General Equipment Co., Ltd. designs and builds diverter dampers in its own 86,600 m² workshop in Hangzhou — as a subsidiary of XIZI Clean Energy Equipment Manufacturing (stock code 002534), and the drafter of the Chinese design and manufacturing standard for flue gas diverter dampers.
Frames covered: T130, FT8, 6B, 6FA, 9E, 7FA, V94.2, SGT5-4000F, 9F, 9HA, SGT5-8000H and M701J, on GE, Siemens, MHI and Ansaldo machines — with OEM and ODM supply to your own drawings. See also our full flue gas damper range.

How a Diverter Damper Works: One Blade, Two Positions, 90 Degrees
The blade pivots on a single shaft. Its position decides where every kilogram of exhaust goes.

• Fully open (90°) — exhaust flows straight into the heat recovery boiler. The unit runs in combined cycle and every unit of heat goes to steam generation.
• Fully closed (0°) — exhaust turns upward into the bypass stack and is discharged. The gas turbine keeps running while the HRSG or steam side is offline.
• Intermediate positions — with a modulating actuator the blade holds any angle, so flow to the HRSG can be trimmed during start-up, shutdown and transient duty.
• Never both closed — the two outlets cannot be closed at the same time by design, so the gas path is never blocked against the turbine.
Inside the Sealing System: How 100% Isolation Is Achieved
The sealing package is what separates a real HRSG diverter damper from a simple flap valve.
• Seal air ring — a high-pressure air fan feeds the double-deck flexible sealing fins and the fixing gland on the casing through pipes, forming a continuous ring of sealing air around the blade.
• 500 Pa above exhaust — the seal air pressure is designed 500 Pa higher than the gas inside the duct, so exhaust cannot pass the blade: 100% isolation with seal air on, 99.95% without.
• Insulated sandwich blade — double-blade structure with intermediate insulation keeps thermal gradients and stresses down during start-stop transients.
• Integrally forged torque tube — no weld seam on the drive torque tube removes a known material risk point.
• Bearings and packing — self-lubricating sleeve bearings (metal alloy with plugged graphite on large frames) and high-temperature graphite packing glands.
• Internal lining — ceramic fiber insulation layers retained by 409 stainless steel liner panels that expand and contract freely.

-
Diverter Damper Control System in CabinetThe material of the cabinet is optional. According to the requirements and the site environment, the cabinet can be designed with carbon steel or stainless steel.read more
-
Diverter Damper with High Sealing PerformanceThe pressure of this volume of seal air is designed to be 500pa higher than the pressure within the exhaust gas, preventing exhaust gas from passing by the blade, and providing a 100% isolation ofread more
-
Diverter Damper for Single CycleThe diverter damper is a change valve with one entrance and two exits; the designed diverter damper is installed horizontally, which can facilitate the flue gas to flow into the HRSG horizontally orread more
-
Duct Diverter Damper Guillotine DamperThe bypass system comprises of Inlet duct, Diverter damper, Guillotine damper, Gas silencer, non-metallic expansion joint at the side of the bypass stack, Bypass steel structure, Bypass stack, andread more
-
Duct Diverter Damper CustomThe bypass system comprises of Inlet duct, Diverter damper, Guillotine damper, Gas silencer, non-metallic expansion joint at the side of the bypass stack, Bypass steel structure, Bypass stack, andread more
-
OEM Diverter Damper IndustryThe diverter damper is a change valve with one entrance and two exits; the designed diverter damper is installed horizontally, which can facilitate the flue gas to flow into the HRSG horizontally orread more
-
Diverter Damper IndustryThe diverter damper is a change valve with one entrance and two exits; the designed diverter damper is installed horizontally, which can facilitate the flue gas to flow into the HRSG horizontally orread more
-
OEM Diverter DamperThe diverter damper is a change valve with one entrance and two exits; the designed diverter damper is installed horizontally, which can facilitate the flue gas to flow into the HRSG horizontally orread more
-
High Quality Duct Diverter DamperThe bypass system comprises of Inlet duct, Diverter damper, Guillotine damper, Gas silencer, non-metallic expansion joint at the side of the bypass stack, Bypass steel structure, Bypass stack, andread more
-
Fire-proof Duct Diverter DamperThe bypass system comprises of Inlet duct, Diverter damper, Guillotine damper, Gas silencer, non-metallic expansion joint at the side of the bypass stack, Bypass steel structure, Bypass stack, andread more
-
Diverter Damper Control System in ContainerThe control of Diverter damper is composed of electrical control system and hydraulic power system. The electrical control system is designed and developed by our company.read more
-
Duct Diverter DamperThe bypass system comprises of Inlet duct, Diverter damper, Guillotine damper, Gas silencer, non-metallic expansion joint at the side of the bypass stack, Bypass steel structure, Bypass stack, andread more
Diverter Damper Configurations We Build
Every configuration below is a real product page. Tell us your frame and duty, and we will point you to the right one.
| Configuration | Duty it is bought for |
|---|---|
| Diverter Damper for Single Cycle | Standard one-inlet / two-outlet unit for single cycle to combined cycle changeover |
| Diverter Damper in HRSG | Installed between gas turbine and HRSG inlet for heat recovery duty |
| Diverter Damper HRSG | Frame-specific design matched to the HRSG inlet geometry |
| Diverter Damper with High Sealing Performance | Double-deck flexible fins plus seal air for 100% isolation |
| Diverter Damper with Seal System | Complete package: fan, ducting, ring seal and damper, commissioned together |
| Electric Diverter Damper | Electric actuator drive, no hydraulic oil system to maintain |
| Adjustable Diverter Damper | Modulating duty: holds intermediate blade positions for flow trimming |
| Bypass Damper | Bypass leg closure damper matched to the diverter |
| Duct Diverter Damper | Duct-mounted configuration for boiler and industrial gas paths |
| Duct Diverter Damper Custom | Built to your duct dimensions, temperature and pressure drop budget |
| Duct Diverter Damper + Guillotine Damper | Matched pair: flow switching plus positive isolation for maintenance |
| Fire-proof Duct Diverter Damper | Fire-resistant construction for special industrial duty |
| OEM Diverter Damper | Built to your drawings and documentation, factory acceptance tested |
| Diverter Damper for Industry | Waste incineration and process gas duty beyond power plant service |
Diverter Damper Technical Parameters
Engineering envelope for the diverter damper itself. Final values are issued with each project drawing package.
| Item | Specification |
|---|---|
| Configuration | One inlet, two outlets; horizontally installed; HRSG side horizontal, bypass side vertical |
| Applicable gas turbines | T130, FT8, 6B, 6FA, 9E, 7FA, V94.2, SGT5-4000F, 9F, 9HA, SGT5-8000H, M701J |
| Design gas temperature | 538–710℃ across delivered projects (710℃ on 9H class) |
| Gas path size | 3300 × 3300 mm up to 8200 × 8200 mm on delivered projects |
| Blade motion | Single shaft, 90° swing; intermediate modulation with positioned actuator |
| Sealing rate | 99.95% without seal air; 100% with auxiliary seal air |
| Seal air pressure | 500 Pa above exhaust gas pressure at the blade perimeter |
| Blade structure | Double-blade insulated sandwich; double-deck flexible metal sealing fins |
| Torque tube | Integrally forged, no weld seam |
| Bearings | Self-lubricating sleeve bearings; metal alloy with plugged graphite on large frames |
| Shaft sealing | High-temperature graphite packing glands, multi-ring |
| Internal lining | Ceramic fiber insulation with 409 stainless steel liner panels |
| Drive type | Hydraulic (2 or 4 cylinders) or electric actuator |
| Emergency closing | Large-capacity accumulator closes within 30 s on turbine trip |
| Control system | In-house electrical control plus hydraulic power unit; PLC with redundant power and CPU; two main pumps |
| Control cabinet | Carbon steel or stainless steel, protection up to IP66; container-mounted option |
| Design codes | ASME, AWS, AISC, EN and ISO practice; EN 1090 and EN ISO 3834 certified welding |
| Factory testing | Damper and control system jointly commissioned in our workshop before delivery |
Temperature and gas path extremes are from delivered project data, not standard catalogue limits. Send your gas conditions if the project sits outside this envelope.
Hydraulic Or Electric Drive?
This is the first choice to make on any diverter damper project. Both are in-house engineered; the trade-offs are below.
| Decision factor | Hydraulic drive | Electric drive |
|---|---|---|
| Emergency closing speed | Accumulator closes the blade within 30 s even on loss of power — the standard choice for turbine-trip duty | 50–60 s stroke time; emergency function depends on the site power supply staying alive |
| Balance of plant | Hydraulic power unit, piping and oil need space, power and routine oil care | Site power only; no oil system, the simplest plant to operate |
| Frame size fit | Standard on large frames 9E to 9HA and M701J, where torque and trip duty dominate | Suits smaller frames and industrial duty with lighter torque demand |
| Control integration | HPU and damper commissioned together in our workshop; PLC redundancy built in | Actuator, limit switches and feedback wired to the same in-house PLC cabinet |
Supplied As Part Of The Complete Bypass System
The diverter damper rarely ships alone. This is the full package scope we deliver and commission as one contract.
Inlet duct. Transition from the gas turbine expansion section to the diverter inlet
Diverter damper. The change valve itself, with drive and sealing system
Guillotine damper. Positive isolation behind the diverter for HRSG maintenance
Gas silencer. Attenuation on the bypass leg
Expansion joints. Non-metallic joints at the bypass stack side
Bypass steel structure. Supports for stack and silencer
Bypass stack. Vertical exhaust stack
Control system. Electrical control plus hydraulic power unit, one supplier, one interface
A typical reference package: duct diverter damper with guillotine damper package — duct, diverter, guillotine, silencer, expansion joints, steel structure and stack, supported by our bypass steel structure and commissioned as one system.
Diverter Damper Projects Delivered
Iraq, 10 sets of 9E diverter dampers shipped with Shanghai Electric
Malaysia, Samalaju bypass system with diverter damper
Uzbekistan, Syrdarya II bypass system first fire
Case wording follows the news pages of this site; confirm the current project names before publishing.
Why Buyers Trust Our Diverter Dampers
Standard drafter. We drafted the Chinese design and manufacturing standard for flue gas diverter dampers.
Invention patents. Flue gas damper and stack damper structure patents, incl. ZL 2007 1 0164658.6 and ZL 2014 1 0004709.9.
Welding certified. EN 1090 and EN ISO 3834 certificates; welding procedures and personnel qualified.
Group backing. Subsidiary of XIZI Clean Energy (002534); ISO 9001 / 14001 / 45001 certified systems.








Diverter Damper FAQ
What does a diverter damper do?
It is a change valve with one inlet and two outlets, installed horizontally behind the gas turbine. Fully open it sends exhaust into the HRSG for combined cycle operation; fully closed it sends exhaust up the bypass stack so the turbine can keep running while the steam side is offline.
How does the seal air system achieve 100% isolation?
A high-pressure fan feeds sealing air through pipes into the double-deck flexible sealing fins and the fixing gland on the casing, forming a continuous ring around the blade. The air is held 500 Pa above the exhaust pressure, so gas cannot pass: 100% isolation with seal air, 99.95% without it.
Can the two outlets be closed at the same time?
No. The design ensures the two outlets can never be closed concurrently, so the exhaust path from the turbine is never blocked against the machine.
Hydraulic or electric drive — which should we choose?
Hydraulic is the standard for large frames and turbine-trip duty because the accumulator closes the blade within 30 s even on loss of power. Electric drive suits smaller frames and industrial duty where no oil system is wanted; its stroke time is 50–60 s.
What happens on a turbine trip?
The hydraulic station carries two main pumps and a large-capacity accumulator that closes the damper within 30 seconds under emergency conditions, protecting the main unit. The PLC has redundant power supply and CPU.
Can you retrofit an existing single-cycle plant to combined cycle?
Yes. We supplied 10 sets of 9E diverter dampers for the Shanghai Electric single-to-combined-cycle retrofit program in Iraq, covering the Diwaniyah, Najaf, Hillah and Karbala sites.
What information do you need to quote a diverter damper?
Gas turbine model, gas path size (inlet and both outlets), design gas temperature and transient profile, sealing requirement, drive preference, control philosophy and site conditions. With these we issue a proposal drawing.
How is the blade built for thermal transients?
The blade is a double-blade insulated sandwich structure, and the internal lining uses ceramic fiber insulation retained by 409 stainless steel liner panels that are held in place but free to expand and contract.
Do you supply the guillotine damper together with the diverter?
Yes, as a matched pair or as the complete bypass package: inlet duct, diverter damper, guillotine damper, gas silencer, non-metallic expansion joints, bypass steel structure and bypass stack, all from one supplier.
How is the diverter damper installed?
It is designed for horizontal installation behind the gas turbine: gas flows horizontally into the HRSG or turns vertically into the bypass stack. Position feedback, limit switches and pressure taps are wired to our control cabinet.
Send Your Turbine Model And Gas Path Size