Hangguo:Your Professional Guillotine Damper Manufacturer!
Hangzhou Hangguo General Equipment Co., Ltd. has been established since December, 2000. As a subsidiary of XIZI Clean Energy Equipment Manufacturing Co,.tld.(Stock code:002534)the Company specializes in the design and manufacture of auxiliary engine and heavy duty equipment for boilers. The company has produced 115 sets of flue gas bypass systems and 152 sets of flue gas baffle doors, covering all continents in the world.
Guillotine Damper Pillar Page Preview
Guillotine Damper Manufacturer in China | HRSG Isolation & Maintenance Barrier Slide Gate Dampers
Hangzhou Hangguo General Equipment Co., Ltd. is a guillotine damper manufacturer and factory in China, a subsidiary of XIZI Clean Energy (stock code 002534). We design and fabricate heavy-duty guillotine dampers for HRSG isolation in gas turbine bypass systems — 152 sets of flue gas dampers delivered since 2000, covering GE, Siemens, MHI and Ansaldo gas turbines from 6B up to 9HA and M701J. As the maker — not a trading company — we control welding, machining, assembly and factory testing in our own 86,600 m² plant.
A guillotine damper is a vertically sliding blade gate installed behind the diverter damper and in front of the non-metallic expansion joint at the HRSG side. When the HRSG needs inspection or maintenance, the blade drops and forms a physical barrier between the hot flue gas path and the people working inside the boiler — see our guillotine damper in HRSG for the standard configuration, or send us your duct drawings for a tailored design.
Guillotine damper location: HRSG inlet of a 350MW combined cycle plant in Mexico.
-
Guillotine Damper in HRSGGuillotine damper comprise of hang steel structure, drive system (electric hoist), blade plate, duct and roof door of duct. It is installed behind the diverter damper and front of non-metallicread more
-
Motorised Guillotine DamperGuillotine damper shall be operated only for maintenance of HRSG after the diverter damper is fully closed to the HRSG and mechanically locked.read more
-
Guillotine Damper with Electric HoistAccording to the size and weight of the Guillotine damper, it can be designed as a single electric hoist or two electric hoists to realize the lifting and dropping action of the Guillotine damper.read more
-
Guillotine Damper System with Control BoxIt is ensured that products are within quality guarantee period, including “three guarantees” (for repair, replacement or compensation of faulty products).read more
-
High Stability Guillotine Damper SystemAll the edges of the guillotine damper are equipped with high strength flexible sealing plates, which play the role of high sealing and low leakage.read more
Why a Guillotine Damper Exists: the HRSG Maintenance Interlock
The guillotine damper is not a flow-control valve. It is a personnel safety barrier that only moves at two moments: when the plant is being switched between operating modes for maintenance. The operating logic below is hard-wired into every system we ship.
This interlock sequence follows the same practice described for our diverter dampers — the two damper families always work as a pair in a bypass system.
Hanging structure and electric hoist drive of a guillotine damper awaiting shipment.
Five Components of Every Hangguo Guillotine Damper
| Hanging steel structure | Carries the full blade weight above the duct; sized for thermal growth and seismic loads. |
| Drive system — electric hoist | One or two wire-rope hoists lift and lower the blade; selected by blade size and weight. |
| Blade plate | Flat sliding gate, stress-relieved, with high-strength flexible sealing strips on all edges. |
| Duct section | Matched inlet and outlet spool pieces; round, square or rectangular to suit your layout. |
| Roof door of duct | An access door in the duct roof so the blade track and seals can be inspected safely. |
Guillotine Damper Models: Which System Fits Your Plant
Every model below is engineered to order. Click through for drawings and configurations, or send us your duct dimensions, gas temperature and drive preference for a same-week quotation.
| Model | Positioning | Key engineering points |
|---|---|---|
| Guillotine Damper in HRSG | Standard HRSG isolation gate | Inlet and outlet dimension 7,800 × 7,800 mm on delivered projects; mounted behind the diverter damper. |
| Guillotine Damper with Electric Hoist | Wire-rope hoist drive | Single or dual hoist selected by blade size and weight; stable lifting and dropping action. |
| Guillotine Damper System with Control Box | Complete system + control | Control box built from Schneider, ABB or Siemens components; dual-hoist synchronising with internal interlock; PLC optional. |
| High Stability Guillotine Damper System | Dedicated running track | Specially equipped running track keeps blade travel stable when driven by electric hoist or winch. |
| Motorised Guillotine Damper | Motorised operation | Operated only for HRSG maintenance after the diverter damper is fully closed to the HRSG and mechanically locked. |



Drive Options: Single Hoist, Dual Hoist or Winch
| Drive | How it works | Choose it when |
|---|---|---|
| Single electric hoist | One wire-rope hoist lifts and lowers the blade on the running track. | Small to medium blade sections where one lifting point keeps the plate square. |
| Dual electric hoists | Two hoists run synchronously with an internal interlock so both ropes stay load-balanced. | Large or heavy blades; the control box keeps both sides moving together — proven in dozens of projects. |
| Winch on running track | A winch drives the blade along a specially equipped track for very stable falling and rising. | Tall ducts or restricted headroom where a winch gives finer control than a hoist. |
Control Box: Relays You Can Source Anywhere
The control cabinet is designed by our engineers after multiple verification rounds and has been used in dozens of projects. It uses high-reliability relays, contactors and buttons from Schneider, ABB or Siemens — pure relay control, so your maintenance team can source spares anywhere in the world. Where the project requires it, we design the same cabinet around a PLC to coordinate hoist movements with the plant DCS.
Key behaviours: two-hoist synchronous action with internal interlock; operation inhibited unless the diverter damper is fully closed and mechanically locked; local push-button control as standard, DCS integration on request.

Guillotine Damper Technical Parameters
| Function | HRSG isolation and maintenance barrier; no flow modulation duty |
| Installation position | Behind the diverter damper, in front of the non-metallic expansion joint at the HRSG side |
| Duct cross-section | Round, square or rectangular — supplied to match your layout |
| Largest section delivered | 7,800 × 7,800 mm inlet and outlet (HRSG project) |
| Sealing | High-strength flexible sealing plates on all blade edges; high sealing, low leakage |
| Interlock logic | Operable only after the diverter damper is fully closed to the HRSG and mechanically locked |
| Drive | Electric hoist (single or dual, synchronised) or winch on a dedicated running track |
| Control | Pure relay control with Schneider / ABB / Siemens components; PLC and DCS integration on request |
| Blade construction | Hanging steel structure, blade plate, duct and roof door of duct |
| Materials | Painted carbon steel or stainless steel; internals selected for flue gas temperature |
| Design pressure / velocity | Up to 1 PSI and 4,000 FPM process air; higher on request |
| Track record | 152 sets of flue gas dampers supplied; models covered include T130, FT8, 5B, 6B, 6FA, 9E, 7FA, V94.2, SGT5-4000F, SGT5-5000F, 9F, 9HA, SGT5-8000H, M701J |
Where Buyers Use Guillotine Dampers
Delivered Projects & Qualifications


Recent guillotine & damper shipments
- M701J smoke damper doors shipped for a 350MW combined cycle project (Mexico Manzanillo III) — gas turbine synchronised on first fire.
- Main chimney damper doors supplied to Korea BHI, loaded April 2025.
- Damper packages inside 700 t bypass system consignments for Central Asia and Southeast Asia projects.
- Guillotine sections sized up to 7,800 × 7,800 mm delivered for HRSG retrofit duty.
Qualifications backing every order
- Drafting unit of China's flue gas damper industry standard.
- EN 1090, EN 3834 and EN 13084 certified fabrication for steel stacks and dampers.
- ISO 9001 / 14001 / OHSAS 18001 quality, environment and safety systems.
- Patented damper structures — including flue gas damper and stack damper patents granted in China.
Full company profile: About Hangguo | Parent listed group: XIZI Clean Energy, stock code 002534.
Frequently Asked Questions
| Why can the guillotine damper only be operated after the diverter damper is fully closed? | Because its duty is personnel protection, not flow control. The interlock guarantees a verified steel barrier exists before anyone enters the HRSG. Operating the guillotine against an open diverter would put the blade directly into a live gas stream. |
| How do I choose between a single and a dual electric hoist drive? | It depends on blade size and weight. Small blades run fine on one hoist; large sections need two hoists running synchronously with an internal interlock so the plate stays level. Tell us the duct dimensions and we size the drive. |
| What components are inside the control box, and can we get PLC control? | The standard cabinet is pure relay control built from Schneider, ABB or Siemens components so spares are available worldwide. For projects that need it, we redesign the same cabinet around a PLC and integrate with your DCS. |
| How is leakage controlled when the blade is closed? | All edges of the blade carry high-strength flexible sealing plates. Combined with the seal frame, they deliver high sealing and low leakage across the temperature range of gas turbine exhaust duty. |
| Where exactly is the guillotine damper installed in the bypass system? | Behind the diverter damper and in front of the non-metallic expansion joint at the HRSG side. This position lets the blade isolate the boiler while the expansion joint absorbs thermal movement. |
| What is the roof door of the duct for? | It is an access opening in the duct roof so your team can inspect the blade track, seals and hoist connections without cutting the duct — a small feature that saves significant maintenance time. |
| What is the largest size you have built? | Delivered projects include guillotine dampers with 7,800 × 7,800 mm inlet and outlet. Round, square and rectangular sections are all manufacturable to your layout. |
| Can the duct and blade be stainless steel? | Yes. Standard supply is painted carbon steel; stainless steel and other materials are available on request, selected against gas temperature and corrosion duty. |
| Hoist or winch — which drive is more stable? | Both run on a dedicated track. For tall ducts or sites with restricted headroom we recommend the winch option for finer control during falling and rising; for standard heights the electric hoist system is the proven choice. |
| What do you need from us to quote a guillotine damper? | Duct dimensions and orientation, gas temperature and flow, drive preference (hoist, dual hoist or winch), control level (relay or PLC) and site conditions such as seismic or wind loads. Drawings speed everything up; a duct outline sketch is enough to start. |
Send your duct dimensions, gas temperature and drive preference to hgtypublic@chinaboilers.com — our engineers reply with sizing and price within one working day. Factory-direct, no trading company margin.
We're professional guillotine damper manufacturers and suppliers in China for over 20 years, featured by good service and competitive price. We warmly welcome you to buy high quality guillotine damper made in China here from our factory.
Guillotine Damper In HRSG, Guillotine Damper System With Control Box