Jan 21, 2022

What are the effects of slagging in high-power gas steam generators

Leave a message

What are the effects of slagging in high-power gas steam generators


What are the effects of slagging in high-power gas steam generators? The slagging of high-power gas steam generators not only increases the workload of boiler operation protection and inspection, but also seriously endangers safe and economical operation, or forces the furnace to reduce load operation or even stop the furnace. The slagging itself is a huge physical and chemical process, and it also has the characteristics of automatic aggravation. Once slagging occurs in the boiler, the heat transfer is deteriorated due to the thermal resistance of the slag layer. !


The slagging of the nozzle of the igniter changes the kiss flow structure at the outlet of the igniter, which damages the atmospheric dynamic conditions in the furnace and affects the ignition process. When the nozzle is blocked due to severe slagging, the steam boiler has to reduce the load to operate, or shut down.


The slagging of the water-cooled wall will cause uneven heating of each part, which is not dangerous for the natural circulation of the water and controls the thermal error of the water-cooled wall.


After the slagging of the heating surface of the gas steam generator, the heat transfer resistance will increase, the heat transfer will be weakened, the heat received by the working medium will be eliminated, the exhaust gas temperature will increase, the exhaust heat loss will increase, and the boiler efficiency will decrease. The high-power gas-fired steam generator maintains the normal operation of the boiler. When adding fuel, it is necessary to increase the air volume accordingly, which increases the load of the supply and induced draft fans, and increases the power consumption of the plant. Therefore, the slagging makes the steam boiler operate. economy has declined significantly.


When the heating surface is slagging, in order to maintain the normal operation of the steam generator, it is necessary to increase the air volume. If the capacity of the ventilation equipment is limited, and the slagging is simple, the flue gas channel is partially blocked, the flue gas resistance increases, and the fan air volume is difficult to increase, so it is necessary to reduce the load.


After slagging on the heating surface of the high-power gas steam generator, the temperature of the flue gas at the outlet of the furnace increases, resulting in an increase in the superheated air temperature. In addition, the thermal error formed by the slagging can easily cause the superheater to be damaged by overheating. At this time, in order to maintain the superheated temperature and protect the reheater, it is also necessary to limit the load during operation.


Send Inquiry