If you want a more efficient turbine/heat recovery steam generator combination, look no further: Hangzhou Hangguo General Equipment Co., Ltd. offers innovative solutions for standard bypass damper systems.

The HRSG bypass damper is installed between the gas turbine and the heat recovery steam generator (HRSG) in a combined cycle power plant. Therefore, dampers must be designed for the extreme conditions they experience. Hangzhou Hangguo's advanced damper system features rugged design, efficient operation and greater reliability. The dampers are designed with safety in mind, reducing operating hazards and maintenance costs while increasing uptime for more direct power generation.

info-743-350

The Hangzhou Hangguo uses 2 bi-plane dampers instead of one large flap damper. Diverter damper systems control turbine exhaust gas (TEG) flow between bypass stacks or HRSGs. Hangzhou Hangguo's HRSG isolation damper allows exhaust gases to enter the HRSG when the bypass damper is closed, and forces the exhaust gases to flow up the bypass chimney when the isolation damper is closed and the bypass damper is opened. The system also features a mechanical interlock that prevents both dampers from closing simultaneously, reducing inspection and maintenance risks.

 

Hangzhou Hangguo's dual damper arrangement is designed for peak or backup systems to meet peak power demands. It allows the waste heat boiler to come online quickly and shut down the flow to the waste heat boiler when peak demand is reached.


Common single vane or flap damper systems direct the exhaust gases to the HRSG at the bottom of the inlet duct when activated, creating a thermal gradient across the duct and HRSG. However, poor airflow from slightly open blades at startup can lead to higher temperature differences, which can create stresses in the structure that shorten equipment life. The disc damper's shaft is mounted on one end, making it difficult to maintain straight blades for proper sealing. Due to the lack of reliability of the damper, a gate damper is provided behind the damper to ensure safety. Additionally, when a waste heat boiler is operating, heat escapes into the chimney, reducing overall efficiency.
 

Unlike single blade dampers, the dual biplane damper configuration allows exhaust gases to enter the chimney and waste heat boiler more evenly, thereby significantly reducing temperature gradients throughout the structure. Likewise, the dual multi-vane dampers enable a "soft start", a gradual transfer of turbine exhaust gases from the bypass stack to the waste heat boiler, significantly mitigating thermal shock to both. Less stress means longer equipment life and lower maintenance costs. Since the biplane design is air-sealed, a guillotine damper is not required.

 

The multi-blade design also allows for more operational control, so operators can better match the steam generator's output to existing loads, increasing efficiency. Without a damper system, the only control parameter available is to limit the gas turbine output, resulting in a loss of marketable power.

Hangzhou Hangguo is designed to incorporate security in two ways.

info-635-340

The first system prevents simultaneous closing of the HRSG inlet and bypass dampers by mechanically linking the two dampers together. The design requires a damper to be opened 80% to ensure that the turbine exhaust is not completely blocked. A mechanical interlock between the HRSG inlet damper and bypass damper keeps both dampers open, locking the open damper over 80o while the paired damper is closed over 10o. This linkage ensures padlock protection for maintenance personnel while isolating the HRSG.

The second safety method uses an air sealing system that pressurizes the blade cavity above the exhaust pressure, creating an air curtain that allows access to the HGSG inlet for inspection or maintenance. It is designed to keep temperatures below OSHA requirements (140 degrees Fahrenheit), which is required for areas classified as confined spaces.

The damper blades themselves are a truss design (or bridge structure) that creates a cavity for the air sealing system. In this system, two fans at 200% capacity help maintain sealing air when the damper is in the closed position. To reduce sealing air requirements, our damper designs use flexible sealing packages to provide sealing to the blade tips. These seals are used on the upstream and downstream edges of adjacent blades and are bolted to the blade edges.

The truss design also maximizes the rigidity of the louver blades, allowing the damper to operate under the rapid temperature changes experienced in this application. The upstream side of the blades is also insulated, reducing heat loss from closing the damper.

Carbon packing with a purge collar is also used in this application to protect the carbon parts from exposure to corrosion and oxidation temperatures above 753oF (400oC). It is equipped with a close-coupled self-aligning flange block bearing assembly with high-temperature inserts. While it allows shaft movement in both rotational and axial directions, it does not require external lubrication that can attract dirt and abrasives. The shaft itself is made from 17-4PH "high strength" stainless steel.

When evaluating a HRSG bypass damper system, keep in mind the basic requirements it should meet:

Under maximum airflow conditions, the damper must ensure zero leakage from the damper when the bypass stack or waste heat boiler is closed.
Maintenance personnel should have safe access to the HRSG when the gas turbine is operating at full load, the HRSG is isolated by dampers, and the sealed air system is operating with appropriate ventilation.
‍